Do you have a question about the Traub TX8i-s and is the answer not in the manual?
Guidance on testing and servicing the fire protection device.
Schedule detailing lubrication tasks and frequencies.
200-hour maintenance for hydraulic system, checking pressure and oil level.
200-hour maintenance for chip conveyor, cleaning around level switch.
200-hour maintenance for central lubrication unit, checking filling level.
200-hour maintenance for pneumatic system, checking filters and pressure.
200-hour maintenance for power clamping chuck, cleaning and lubrication.
1000-hour maintenance for pneumatic system, replacing active-carbon filter.
2000-hour maintenance for hydraulic system, replacing filter cartridge.
2000-hour maintenance for axes, checking grid spacing and reference points.
2000-hour maintenance for ball screw transmission, determining reversing backlash.
4000-hour maintenance for hydraulic system, replacing hydraulic fluid.
4000-hour maintenance for power clamping mechanism, checking concentricity.
4000-hour maintenance for control cabinet, cleaning interior and retightening connections.