59
10.2016
WTAL - TNX65/42
Safety-related maintenance every 1, 2, 4 and 8 years
G
Safety-related maintenance every year
No. Where What Comments
01 Emergency OFF
button
• Check Emergency OFF function Switch on the
machine
02 Automatic working
area door
• Check mechanical switch strip Switch on the
machine
03 Repeat blowing unit • Check storage batteries and replace them if
necessary
Switch on the
machine
Maintenance required every 2 years for safety reasons
04 Repeat blowing unit • Replace storage batteries
05 Uninterruptible
power supply
• Replace storage batteries
(optional)
Maintenance required every 4 years for safety reasons
06 Control cabinet /
control console
• Replace PC buffer batteries if necessary
• Replace NC buffer batteries if necessary
Switch on the
machine
07 Control cabinet • Check buffer batteries and replace if necessary
Maintenance required every 8 years for safety reasons
08 Working area door • Replace window pane