EasyManua.ls Logo

Traub TX8i-s - Emergency OFF function check

Default Icon
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
60
10.2016
WTAL - TNX65/42
Safety-related maintenance every 1, 2, 4 and 8 years
Annual check of Emergency OFF function
This maintenance work can only be carried out when the machine is
switched on.
Correct operation of the Emergency OFF buttons in the machine must be
checked annually.
At least one axis must be driven for this purpose.
This check should not be performed during a machining operation, otherwise
the machine may be damaged.
Press Emergency OFF button
Drives are stopped instantly
The following message must appear on the screen:
Emergency OFF machine
G01