27
10.2016
WTAL - TNX65/42
Maintenance work every 200 hours of operation
Standard
2
1
Tool magazine
4
5
Milling unit
3
Pneumatic system
• Examine all filter in the maintenance unit for signs of fouling and replace if
necessary.
Maintenance unit Spare filter cartridge Article No. Item
Standard
Activated carbon mini
Set
476138.8251
476138.8181
1
2
Milling unit 40 µm 476138.8301 3
Tool magazine
40 µm
5 µm
476138.8141
476138.8151
4
5
The required air pressure must be set to 6 bar.
• Check and correct the air pressure if necessary.
B04