27
10.2016
WTAL - TNX65/42
Maintenance work every 200 hours of operation
Standard
2
1
Tool magazine
4
5
Milling unit
3
Pneumatic system
Examine all filter in the maintenance unit for signs of fouling and replace if
necessary.
Maintenance unit Spare filter cartridge Article No. Item
Standard
Activated carbon mini
Set
476138.8251
476138.8181
1
2
Milling unit 40 µm 476138.8301 3
Tool magazine
40 µm
5 µm
476138.8141
476138.8151
4
5
The required air pressure must be set to 6 bar.
Check and correct the air pressure if necessary.