9
10.2016
WTAL - TNX65/42
Maintenance Instructions
Risk of fire and explosion!
The machine must not operate unattended when using
inflammable lubricoolants.
Danger due to electricity
Work on motors or other electrical assemblies may only be carried
out by specially trained and instructed personnel!
Danger due to electricity
Even when the machine has been switched off, electricity may still
be stored in the electric components. These components are
identified by a corresponding sign and must not be touched until the
specified discharge time has expired.
Depressurize hydraulic system
Before starting any maintenance or repair work, the entire hydraulic
system must be depressurized via the accumulator drain valve.
Disconnect compressed air supply from the machine
Before starting any maintenance work on the machine, the
compressed air supply must be disconnected from the machine by
turning the manual knob on the air maintenance unit.
Health hazard!
Do not allow lubricoolants to come into contact with the skin.
Appropriate skin care agents must be used.
Vapour extractors must be fitted to prevent inhalation of
physiologically harmful substances.
Safety instructions
The safety instructions contained in this manual must be observed
without fail!
Accumulator ≤ 1 l
Accumulators with a volume ≤ 1 l are not subject to mandatory
testing in accordance with Pressure Equipment Directive (PED)
97/23/EC. CE marking and a declaration of conformity are not
permitted for these accumulators.
Fuels
The information in the data sheets of the fluid manufacturers and in
the document Notes on Operating Materials must be observed
during all work involving fuels and fluids.
The filling quantities of the fuels and fluids are stated in the
respective fluid schedules.
Locally applicable guidelines and regulations must be observed
when disposing of auxiliaries, coolants and lubricants.