Model 3430
3-19
where:
WD = Wet density in kg/m
3
or pcf
% MA = Percent Marshall (This value is valid only if an
appropriate target has been entered for the material
being tested.)
DD = Dry density in kg/m
3
or pcf
MOIST = Moisture value in kg/m
3
or pcf
% MOIST = Percent moisture
% VOIDS = 100 (1 – WD/VOIDLESS)
100 – % MA = Value given by subtracting the percent
Marshall value from 100
MOIST CR = Moisture count ratio
DENS. CR = Density count ratio
M Count = Moisture counts as read by the gauge
D Count = Density counts as read by the gauge
(Use & keys)
xxxxx PCF
DD:
xxxxx PCF
xx.x %
Moist:
% Moist:
xx.x %
xx.x %
% VOIDS
100 % MA
MOIST CR: xx.x
DENS CR: xx.x
M Count: xxxxx
D Count: xxxxx
PCF
xx.x %
WD: xxxxx
% MA
GAUGE OPERATION