TRUE ICE truemfg.com
TEC_TM_171 | REV. G | EN
P#224534
02/28/2024 Page 14 of 72
About Your Ice Machine & Installation Requirements (cont.)
Ice Machine Specifications
Air-cooled ice machine clearances
Model
Sides Top Back
TCIM/TI-422 6" (152.4 mm) 6" (152.4 mm) 6" (152.4 mm)
TCIM/TI-430 3" (76.2 mm) 6" (152.4 mm) 6" (152.4 mm)
TCIM/TI-522 6" (152.4 mm) 6" (152.4 mm) 6" (152.4 mm)
TCIM/TI-530 3" (76.2 mm) 6" (152.4 mm) 6" (152.4 mm)
TCIM/TI-622 3" (76.2 mm) 12" (304.8 mm) 6" (152.4 mm)
TCIM/TI-630 3" (76.2 mm) 6" (152.4 mm) 6" (152.4 mm)
Air-cooled ice machine specifications
Model 24 Hour Production Min./Max.
Batch
Weights
Potable Water
Consumption
(90˚F Air/
70˚F Water)
Electrical
Consumption
(90˚F Air/
70˚F Water)
Peak Heat of
Rejection
70˚F Air/50˚F Water 90˚F Air/70˚F Water
TCIM/TI-422 450 lb (188 kg) 395 lb (159 kg)
3.7–4.6 lb
(1.7–2.1 kg)
14.0 gal/100 lb 3.8 kwh/100 lb 6400 BTU/hr (1.88 kW)
TCIM/TI-430 450 lb (188 kg) 385 lb (159 kg)
3.7–4.6 lb
(1.7–2.1 kg)
14.0 gal/100 lb 3.75 kwh/100 lb 6700 BTU/hr (1.96 kW)
TCIM/TI-522 550 lb (249 kg) 500 lb (227 kg)
4.7–5.6 lb
(2.1–2.5 kg)
14.0 gal/100 lb 4.00 kwh/100 lb 8400 BTU/hr (2.46 kW)
TCIM/TI-530 590 lb (268 kg) 530 lb (240 kg)
4.7–5.6 lb
(2.1–2.5 kg)
14.0 gal/100 lb 3.75 kwh/100 lb 8400 BTU/hr (2.46 kW)
TCIM/TI-622 630 lb (285 kg) 580 lb (263 kg)
4.7–5.6 lb
(2.1–2.5 kg)
14.0 gal/100 lb 4.00 kwh/100 lb 8800 BTU/hr (2.58 kW)
TCIM/TI-630 630 lb (285 kg) 580 lb (263 kg)
4.7–5.6 lb
(2.1–2.5 kg)
14.0 gal/100 lb 3.80 kwh/100 lb 8800 BTU/hr (2.58 kW)
Fig. 1. Interior view of side panel with air filter. Right side shown.
Louver Grill Cover Air Filter
*Both interchangeable