TRUE ICE
TEC_TM_171 | REV. G | EN 02/28/2024 Page 59 of 72
truemfg.com
Maintenance & Servicing (cont.)
After Cleanup...
1. Promptly place all lamp debris and cleanup materials outdoors in a trash container or protected area until materials can be disposed of.
Avoid leaving any lamp fragments or cleanup materials indoors.
NOTICE
Some localities require fluorescent lamps (broken or unbroken) be taken to a local recycling center. Check with your local
government about disposal requirements in your area. If there is no such requirement, you can dispose of the materials with your
household trash.
2. If practical, continue to air out the room where the lamp was broken and leave the heating/air-conditioning system shut off for
several hours.
Recommended Cleaning Frequency
NOTICE!
Maintenance procedures are not covered by warranty.
It is the User's responsibility to keep the ice machine and ice storage bin (or dispenser if applicable) in a sanitary condition in accordance
with the instructions in this manual.
When using a non-True Manufacturing bin or dispenser, follow the maintenance guidelines of the manufacturer of the product.
The maintenance schedule below is a guideline. More frequent maintenance may be required depending on water quality, environment,
and local sanitation regulations.
Recommended cleaning schedule
Recommended Maintenance Schedule
Frequency Component Task
Daily
Ice Scoop Clean with sanitizer or neutral cleaner and rinse thoroughly.
Air Filter Inspect and wash with warm water and neutral cleaner if dirty.
Water Filter
Check the "Water Passed Through Filter" counter in the "Counters"
section in
the "MENU" screen.
Monthly
Water Filter Check for proper outlet pressure and change if less than 20 psig (138 kPa)
Ice Machine and Bin
Exterior (or dispenser, if
applicable)
Wipe surfaces with a damp cloth rinsed in water to remove dust and dirt from the
outside of the ice machine and bin. For greasy residue use a damp cloth rinsed in a
mild dish soap and water solution. Wipe dry with clean, soft cloth.
The exterior panels have a clear coating that is stain resistant and easy to clean.
Products containing abrasives will damage the coating and scratch the panels.
Quarterly Ice Machine Preventative Maintenance Cleaning and Sanitizing Procedure.
Bi-Annually
Ice Machine and Bin (or
dispenser, if applicable)
Descaling and Sanitizing Procedure.
As Directed by Service
Professional
Air Cooled Condenser
In areas with airborne contaminates (i.e. grease), chemical cleaning of the condenser
will be required. This should only be done by a service professional.