TRUE ICE
TEC_TM_171 | REV. G | EN 02/28/2024 Page 3 of 72
truemfg.com
Installation & Setup Checklist
Is the ice machine level?
Is the ice machine located where the ambient temperature is within 35˚-110˚F (1.7˚- 43.3˚C) and the water temperature within
35˚-110˚F (1.7˚-43.3˚C) all year around?
Does the ice machine have the proper clearance for air circulation and service? See "Ice Machine Specifications" (pg. 14).
If present, are the air filter and blank cover installed on the correct side to meet clearance requirements?
Have all shipping materials been removed from the ice machine's exterior and interior?
Is the ice machine on a dedicated electrical circuit?
Have all electrical and water connections been made?
Do electrical and water connections meet applicable laws, codes, and regulations?
Has the power supply voltage been checked or tested against the nameplate rating?
Has a proper ground been installed to the ice machine?
Are the water supply and drain lines sized as specified (pg. 21)?
Are the shut-off valve(s) and drain valve(s) installed?
Is the water supply pressure between 20-100 psig (138-689 kPa)?
Is the compressor snug on all mounting pads?
Have the refrigerant lines been checked to ensure they do not rub or touch other lines or surfaces?
Has the fan blade (if applicable) been checked to ensure it turns freely?
Has the end user been given the instruction manual, as well as instructed on how to operate the ice machine and the
importance of the recommended periodic maintenance?
Has the end user been given the contact information for an authorized service agent?
Has ice machine and bin/dispenser been sanitized per the manufacturer's instructions?
Is the drain line vented?