TRUE ICE
TEC_TM_171 | REV. G | EN 02/28/2024 Page 23 of 72
truemfg.com
To setup your water filter, see the following instructions.
1. In the upper right corner of the screen, press Menu .
2. In the Menu screen, press Water Filter.
3. In the Water Filter screen, select the appropriate water filter
for your application. TRUE offers Standard and Platinum water
filtration systems. If using a non-TRUE water filter, enter the
water capacity under CUSTOM. See filter capacities in the
water filter capacities table.
About Your Ice Machine & Installation Requirements (cont.)
Filter Type Capacity
Standard 14,000 gal (52,996 L)
Platinum 35,000 gal (132,490 L)
Custom (default) 10,000 gal (3,7854 L; adjustable)
Drain Requirements
• Run the ice machine drain line, dispenser unit/ice storage bin drain line, and water-cooled condenser drain line (if applicable)
separately.
• For optimum flow, drain lines must have 1/4" fall per 12" (20 mm fall per 1 m) of horizontal run.
• For correct drain flow, install a vented tee connection.
• Vent the sump drain. A vertical vent at the back of the drain, extended approximately 8-10" (203-254 mm) will allow the gravity drain
to empty and keep any surges during draining from discharging water out the vent.
• DO NOT directly pipe drain lines to the sewer system. Keep a vertical air gap [2" (50.8 mm) minimum] between the drain line ends
from the ice machine and condensation drain, dispenser unit/ice storage bin, and water-cooled condenser (if applicable) and the
floor drain.
• Insulate drain tubing in humid environments.
Water Filter Setup
TRUE recommends water filters for all ice machines. Water filters help remove particulate that reduces operating efficiency and equipment
life. Regularly changing water filters is essential for optimum-quality ice, reduced maintenance, and prolonged equipment operation.