EasyManuals Logo

TSC ME240 User Manual

TSC ME240
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #48 background imageLoading...
Page #48 background image
43
A. Gap Mode
Press the and buttons to scroll the cursor to the media type and press the
button to enter the sensor calibration mode.
Note: If printing from enclosed software/driver, the software/driver will send out the
GAP or BLINE command, which will overwrite the sensor type setting set from
the front panel.
A-1 Automatic
When enter the [Automatic] option, you will see following message, and printer will
feed 2 to 3 gap labels to calibrate the sensor sensitivity automatically. When
calibration is completed, the LCD screen will return to the previous menu.
A-2 Manual
In case Automatic sensor calibration cannot apply to the media, please use
“Manual” function to calibrate the gap sensor manually.
When enter [Manual] option, you will see following message. Please complete those
steps
Paper Len.
00812 dot
1. Press the button to move
the cursor from left digit to right digit,
and press the button to set
the value from 0 to 9 and the dot/
mm/ inch. Press the
button to set the paper length into the
printer.
Calibration 1/4
>
Gap Mode
Bline Mode
Cont. Mode
Gap Mode 1/4
>
Automatic
Manual
Pre-Printed
Gap Mode
Automatic
Gap Mode 2/4
Automatic
>
Manual
Pre-Printed

Other manuals for TSC ME240

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TSC ME240 and is the answer not in the manual?

TSC ME240 Specifications

General IconGeneral
Resolution203 dpi / 300 dpi
Operating Temperature5°C to 40°C (41°F to 104°F)
Print MethodThermal Transfer & Direct Thermal
InterfaceUSB
Power SupplyAC 100-240V, 50/60Hz
Humidity20% to 85% RH (non-condensing)

Related product manuals