71
The default IP address is obtained by DHCP. To change the setting to static IP address,
click Static IP radio button then enter the IP address, subnet mask and gateway. Click Set
IP to take effect the settings.
Users can also change the Printer Name by another model name in this fields then click
Set Printer Name to take effect this change.
Note: After clicking the Set Printer Name or Set IP button, printer will reset to take
effect the settings.
8. Click Exit button to exit the Ethernet interface setup and go back to Diagnostic Tool main
screen.
Factory Default button
This function will reset the IP, subnet mask, gateway parameters obtained by DHCP and
reset the printer name.
Web setup button
Except to use the Diagnostic Utility to setup the printer, you can also explore and configure
the printer settings and status or update the firmware with the IE or Firefox web browser.
This feature provides a user friendly setup interface and the capability to manage the printer
remotely over a network.

Other manuals for TSC ME240

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TSC ME240 and is the answer not in the manual?

TSC ME240 Specifications

General IconGeneral
Resolution203 dpi / 300 dpi
Operating Temperature5°C to 40°C (41°F to 104°F)
Print MethodThermal Transfer & Direct Thermal
InterfaceUSB
Power SupplyAC 100-240V, 50/60Hz
Humidity20% to 85% RH (non-condensing)