Revision C – January 2023
CDS2000 Page | 33
System
Settings
Flowmeter
Size
Timer
Settings
Pump
Settings
CDS2000SetupMenu
*ProgrammableDefaultSettingsarehighlightedin*Blue
Ena bleLinearizer
*Disabled
Enabled
Metrology
Configuration
(continued)
Calibration
AverageKFactor:
*150.00
SizeOptions:
½”
5/8"
¾”
1"
1¼”
1½”
*2"
3"
4"
MaxTimeBetween
Deliveries:
*15000se conds
Pressure
Temperature
Leak
PumpCoold own
Mode:
*Disabled
ProductSensor
PumpHousing
DefaultSettingswhen
“Pr oductSensor”is
enabled:
TemperaturetoEnable
Timer=*100F
PumpCooldownTime=
*600seconds
DefaultSettingswhen
“PumpHousingis
enabled:
TemperaturetoEnable
Pump=*150F
PumpRelay
Contacts:
*NormallyClosed
Norm allyOpen
Cavitatio nDetection:
*Disabled
420Input
DefaultSettingswhen
“420Input”isenabled:
PumpThresholdTimer=
*180Seconds
PumpCutoffPressure =
*75PSIG
PumpThresholdPressure
=*150PSIGforLIN
*175PSIGforLOX
*225PSIGforLAR
PumpShutdown
Delay:
*Disabled
Enabled
When“PumpShutdown
Delayisenabled,Pump
ShutdownTime=*60
seconds
LeakDete ct:
*Disabled
Alarm
Alarm+Cutout