8.7 Connecting the device to a Siemens PLC in PROFINET
The following example describes the connection of the devices to a Siemens PLC in PROFINET
by means of the programming software SIMATIC STEP7 Professional V15 (TIA-Portal).
Used Hardware
The following hardware components are used in this example:
n Siemens PLC S7-1500
n IO-Link master TBEN-L5-8IOL with the following configuration:
Port 1: Turck temperature sensor, TS-530-LI2UPN8X-..., IO-Link V1.0
Port 2: Channel used as DI
Port 3: Turck linear position sensor, Li100P0-Q25LM0-..., IO-Link V1.0
Port 4: Channel used as DI
Port 5: Channel used as DI
Port 6: Turck IO-Link hub: TBIL-M1-16DXP, IO-Link V1.1
Port 7: Turck ultra sonic sensor, RU130U-M18E-..., IO-Link V1.1
Port 8: Turck ultra sonic sensor, B2N360-Q42-..., IO-Link V1.1
Used Software
The following software tools are used in this example:
n SIMATIC STEP7 Professional V15 (TIA-Portal)
n GSDML file for TBEN-L…-8IOL (can be downloaded for free as ZIP archive "TBEN-
L_PROFINET.zip" under www.turck.com)
Prerequisites
n The programming software has been started.
n A new project has been created.
n The PLC has been added to the project.