Connection Manager Object (0x05)
This object is used for connection and connectionless communications, including establishing
connections across multiple subnets.
The following description of the Ethernet Link Object is taken from the CIP specification, Vol. 2,
Rev. 2.1 by ODVA & ControlNet International Ltd. and adapted to the Turck products.
Common services
Service code Class Instance Meaning
Dec. Hex.
84 0x54 no yes FWD_OPEN_CMD
(opens a connection)
78 0x4E no yes FWD_CLOSE_CMD
(closes a connection)
82 0x52 no yes UNCONNECTED_SEND_CMD