Commissioning
Commissioning the device in EtherNet/IP™
80
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
TCP/IP Interface Object (0xF5)
The following description of the Ethernet Link Object is taken from the CIP specification, Vol. 2,
Rev. 1.1 by ODVA & ControlNet International Ltd. and adapted to the Turck products.
Class attributes
Attr. no. Designation Get/Set Type Value
Dec. Hex.
1 0x01 Revision G UINT 1
2 0x02 Max. object instance G UINT 1
3 0x03 Number of instances G UINT 1
6 0x06 Max. class identifier G UINT 7
7 0x07 Max. instance attribute G UINT 6
Instance attributes
Attr. no. Designation Get/Set Type Value
Dec. Hex.
1 0x01 Status G DWORD Interface status
2 0x02 Configuration
capability
G DWORD Interface capability flag
3 0x03 Configuration
control
G/S DWORD Interface control flag
4 0x04 Physical
link object
G STRUCT
Path size UINT Number of 16 bit words:
0x02
Path Padded
EPATH
0x20, 0xF6, 0x24, 0x01
5 0x05 Interface
configuration
G Structure of: TCP/IP network interface
configuration
IP address G UDINT Actual IP address
Network mask G UDINT Actual network mask
Gateway addr. G UDINT Actual default gateway
Name server G UDINT 0 = no server address con-
figured
Name server 2 G UDINT 0 = no secondary server ad-
dress configured
Domain name G UDINT 0 = no Domain Name con-
figured
6 0x06 Host name G STRING 0 = no Host Name con-
figured
12 0x0C QuickConnect G/S BOOL 0 = deactivate
1 = activate

Table of Contents