Ultraflux Minisonic II Portable User Manual

Ultraflux Minisonic II Portable
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Ultrasonic flowmeters
Technical manual
Minisonic II
Portable
Question and Answer IconNeed help?

Do you have a question about the Ultraflux Minisonic II Portable and is the answer not in the manual?

Ultraflux Minisonic II Portable Specifications

General IconGeneral
TypePortable Ultrasonic Flow Meter
Accuracy±1% of reading
Repeatability±0.2% of reading
Data LoggingYes
DisplayLCD with backlight
Resolution0.001 m/s
TechnologyTransit-time
Fluid CompatibilityWater, Chemicals, Oils
Power SupplyInternal rechargeable battery or AC power adapter
Outputs4-20 mA, RS-232
Protection ClassIP65
Operating Temperature-20°C to +60°C
Battery LifeUp to 20 hours
Weight1.2 kg
Protection RatingIP65 (electronics), IP68 (transducers)

Summary

Applying a Measuring Point

Choosing Probe Location

Guidance on selecting optimal locations for probe installation.

Choosing a Measuring Mode

Probe Positioning

Straight Pipe Run Measurements

Measurement Near Elbows

Minimum distances required for accurate measurement near pipe elbows.

Measurements Near Fittings

Measurement Near Valves

Distance guidelines for measurements near valves.

Measurement Near Divergents

Distance guidelines for measurements near pipe divergents.

Measurement Near Convergents

Distance guidelines for measurements near pipe convergents.

Selecting Probe Type

Fitting and Connecting Probes

Pipe Preparation for Probes

Steps for cleaning and preparing the pipe surface for probe installation.

Probe Fitting Procedure

Instructions on positioning probes, applying coupling gel, and securing them.

Configuring the Minisonic II

Measurement Screen Presentation

Configuration Menu Navigation

Measurement Configuration

Setting up pipe, fluid, and probe characteristics for measurement.

Measurement Configuration: Pipe

Pipe Characteristic Settings

Configuring external diameter, circumference, thickness, material, and roughness.

Measurement Configuration: Fluid

Fluid Characteristic Settings

Selecting and configuring the properties of the fluid being measured.

Measurement Configuration: Probes

Probe Model and Ultrasonic Path

Selecting probe models and fitting modes (Direct, Reflex, N, W).

Measurement Configuration: Filtering

Measurement Filtering Settings

Adjusting damping, memory, and flow rate cut-off for filtering.

Measurement Configuration: Totalizer

Totalizer Settings

Configuring the totalizer mode, weight, and unit.

Measurement Configuration: Logger

Internal Recorder Setup

Configuring the file name, data number, period, and data type for recording.

Measurement Configuration: Inputs/Outputs

Inputs and Outputs Configuration

Setting up analog and logic outputs for the device.

Measurement Configuration: Low Power Mode

Battery Safety Mode Setup

Configuring power saving modes: Off, Power Saving, Sequencer.

Measurement Configuration: Settings Level

Setup Mode Selection

Choosing between Simple, Normal, and Advanced setup modes.

Measurement Configuration: Config. Management

Configuration Management Options

Managing configurations: Reset, Save, Load, and Delete.

Probe Distance Display

US Signal Display and Analysis

Auto Zero Adjustment

Advanced Measurement Diagnostics

System Configuration

Low Power Mode Operations

Power Saving Mode

Enabling power saving features like OLED display off.

Sequencer Mode

Configuring measurement duration and period for energy saving.

Software Update Procedure

Logger and Data Exploitation

Excel Import and Spreadsheet Formatting

Adjusting Measurement Signal Gain

Gain and Margin Adjustment Modes

Explanation of ESC, Automatic, and Manual modes for gain/margin adjustment.