C39A101 Watchpoint fault:
Motor-Control task
timeout
Same as C39A1
C39A102 Watchpoint fault:
Motor-encoder task
timeout
Same as C39A1
C39A103 Watchpoint fault:
Joint-encoder task
timeout
Same as C39A1
C39A104 Watchpoint fault:
Communication task
timeout
Same as C39A1
C39A105 Watchpoint fault:
RAM-test task
timeout
Same as C39A1
C39A106 Watchpoint fault:
CalVal-test task
timeout
Same as C39A1
C39A107 Watchpoint fault:
ROM-test task
timeout
Same as C39A1
C40A AD-Converter hit
high limit joint
EMC issue external or
electronics internal
Check grounding and
shielding for EMC problems
C41A RC Oscillator Trim
register hit high limit
C42A RC Oscillator Trim
register hit low limit
C43A Change in invariant
memory detected
C43A1 Current sensor gain
C44A CRC check failure on
primary bus
Serial communication
problem with joint or
secondary bus node
a) Check black 2-wire
connectors and wires in
joints.
b) Do a Complete rebooting
sequence.
c) If this happens more than
two times in a row, contact
your local service provider for
assistance.
C44A0 Base
C44A1 Shoulder
Service Manual 101 UR3
7.Troubleshooting
Copyright © 2009–2021 by UniversalRobotsA/S. All rights reserved.

Table of Contents

Other manuals for Universal Robots ur3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Universal Robots ur3 and is the answer not in the manual?

Universal Robots ur3 Specifications

General IconGeneral
BrandUniversal Robots
Modelur3
CategoryRobotics
LanguageEnglish

Related product manuals