C50A84 Last CPU reset
caused by External-
Pin-Reset
C50A85 Last CPU reset
caused by Brown-
Out-Reset
C50A99 Wrong software on
PCB
C50A100 Cable not connected Check cable and connections
between robot and control
box
C50A101 Short circuit in robot
detected or wrong
robot connected to
control box
Check robot type. Look for
short circuit in cable and in
robot arm
C50A102 Voltage rising too
slowly
C50A103 Voltage failed to
reach acceptable
level
C50A104 The IMMI module
does not respond
C51A CRC check failure on
secondary bus
C51A0 Processor B
C51A1 Primary screen
processor
CRC check failure on safety
processor 1 in Teach
Pendant
C51A2 Secondary screen
processor
CRC check failure on safety
processor 2 in Teach
Pendant
C51A3 Primary E67
C51A4 Secondary E67
C53A IO overcurrent
detected
Control Board error Remove all external
connections to I/O-interface
of Safety Control Board.
Check for short circuit
C53A1 IO Overcurrent
detected. Max is
800mA
Service Manual 105 UR3
7.Troubleshooting
Copyright © 2009–2021 by UniversalRobotsA/S. All rights reserved.

Table of Contents

Other manuals for Universal Robots ur3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Universal Robots ur3 and is the answer not in the manual?

Universal Robots ur3 Specifications

General IconGeneral
BrandUniversal Robots
Modelur3
CategoryRobotics
LanguageEnglish

Related product manuals