C74A32 Signal lost
=Misaligned
readhead or
damaged ring
C74A64 Signal low =Too far
from magnetic ring
C74A128 Signal saturation
=Too close to
magnetic ring
C75A Joint encoder error Magnetic encoder error
(absolute encoder).
Argument = sum of C75
errors
Check encoder connections
C75A1 Invalid decode:
Readhead
misalignment, ring
damaged or external
magnetic field
present.
a) Do a Complete rebooting
sequence.
b) Check grounding and
shielding for EMC problems.
c) If this happens more than
two times in a row, replace
joint
C75A2 Speed reading is not
valid
a) Do a Complete rebooting
sequence.
b) If this happens more than
two times in a row, replace
joint
C75A4 System
error=malfunction or
inconsistent
calibration detected
a) Do a Complete rebooting
sequence.
b) If this happens more than
two times in a row, replace
joint
C75A8 Supply voltage is out
of range
C75A16 Temperature is out
of range
C75A32 Signal lost
=Misaligned
readhead or
damaged ring
a) Do a Complete rebooting
sequence.
b) Check grounding and
shielding for EMC problems.
c) If this happens more than
two times in a row, replace
joint
UR3 112 Service Manual
7.Troubleshooting
Copyright © 2009–2021 by UniversalRobotsA/S. All rights reserved.

Table of Contents

Other manuals for Universal Robots ur3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Universal Robots ur3 and is the answer not in the manual?

Universal Robots ur3 Specifications

General IconGeneral
BrandUniversal Robots
Modelur3
CategoryRobotics
LanguageEnglish

Related product manuals