EasyManua.ls Logo

Universal Robots ur3 - Page 140

Universal Robots ur3
231 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
C200A9 3V3A power good pin
is low
Safety Control Board: uP-A
has detected an error
a) Do a Complete rebooting
sequence.
b) If this happens more than
two times in a row, replace
Safety Control Board
C200A10 3V3B power good pin
is low
Safety Control Board: uP-A
has detected an error
a) Do a Complete rebooting
sequence.
b) If this happens more than
two times in a row, replace
Safety Control Board
C200A11 5V power good is
low
Safety Control Board: uP-A
has detected an error
a) Do a Complete rebooting
sequence.
b) If this happens more than
two times in a row, replace
Safety Control Board
C200A12 3V3 voltage too low Safety Control Board: uP-A
has detected an error
a) Do a Complete rebooting
sequence.
b) If this happens more than
two times in a row, replace
Safety Control Board
C200A13 3v3 voltage too high Safety Control Board: uP-A
has detected an error
a) Do a Complete rebooting
sequence.
b) If this happens more than
two times in a row, replace
Safety Control Board
C200A14 48V input is too low a) Do a Complete rebooting
sequence.
b) Check 48 V Power supply,
current distributer, energy
eater and Control Board for
issues
C200A15 48V input is too high a) Do a Complete rebooting
sequence.
b) Check 48 V Power supply,
current distributer, energy
eater and Control Board for
issues
C200A16 24V IO short
circuited
Too high current a) Do a Complete rebooting
sequence.
b) Disconnect external I/O
connections and check
external power supply if
connected
UR3 134 Service Manual
7.Troubleshooting
Copyright © 2009–2021 by UniversalRobotsA/S. All rights reserved.

Table of Contents

Other manuals for Universal Robots ur3

Related product manuals