All rights reserved 83 Servicemanual_UR3_en_rev3.1.2
SCB: uP-A has detected an
error: Wrong SCB
SCB: uP-A has detected an
error
SCB: uP-A has detected an
error
SCB: uP-A has detected an
error
Replace Safety Control
Board (SCB)
SCB: uP-A has detected an
error
Replace Safety Control
Board (SCB)
SCB: uP-A has detected an
error: firmware error
Replace Safety Control
Board (SCB)
Watchdog reset the processor
SCB: uP-A has detected an
error
OVG signal test not passed
SCB: uP-A has detected an
error: over voltage generator
Replace Safety Control
Board (SCB)
3V3A power good pin is low
SCB: uP-A has detected an
error
Replace Safety Control
Board (SCB)
3V3B power good pin is low
SCB: uP-A has detected an
error
Replace Safety Control
Board (SCB)
SCB: uP-A has detected an
error
Replace Safety Control
Board (SCB)
SCB: uP-A has detected an
error
Replace Safety Control
Board (SCB)
SCB: uP-A has detected an
error
Replace Safety Control
Board (SCB)
Check: 48 V power supply,
current distributer energy
eater or replace SCB
Check: 48 V power supply,
current distributer energy
eater or replace SCB
Disconnect external
connections
Motherboard takes too high
current
Check: Short circuit in robot
arm, 48 V power supply,
current distributer energy
eater or replace SCB
Robot voltage is too high
Check: 48 V power supply,
current distributer energy
eater or replace SCB
24V IO voltage is too low
Disconnect I/O or replace
SCB
Check 12 V power supply,
cables or replace SCB
Check 12 V power supply,
cables or replace SCB
It took too long to stabilize
24V
Safety Control Board
error(SCB)
External 24 V problem or
replace SCB