10.5 Reset the controller
If problems, such as inaccurate channel registration
exist, reset the controller. The following illustration
shows the location of the reset button in the controller.
To reset the controller:
1. Make sure the controller is in run mode. If it is in
registration or forced mode, press and hold the OK
button for about 5 seconds or until the LEDs turn
off.
2. Press the <, OK, and > buttons simultaneously (for
about 10 seconds) until the power LED flashes, and
all channel LEDs turn off. All parameters are erased
and run mode has been activated.
10 s
3. Installation and registration are required after
resetting the controller.
10.6 Unregister channels in the
controller
unreg ister on e Chan nel
When a channel is inaccurately registered or if a
thermostat registration needs to be redone, it is possible
to remove the current registration from the controller.
3 s
5 s
21
3
Caution!
Make sure the controller is in run mode.
For information about how to exit to run
mode, see section 10.4 Run mode > Exit to
run mode.
To unregister a channel:
1. Press and hold the OK button on the controller until
the LED for channel 1 flashes red/green, or the first
unregistered channel flashes red.
2. Use buttons < or > to move the pointer (LED
flashes red) to the selected channel (flashes green if
registered) to unregister.
3. Press the < and > buttons simultaneously until the
LED for the selected channel starts flashing red
(about 3 seconds).
unreg ister al l Chan nel
When one or more channels are inaccurately registered,
it is possible to remove all registrations at the same
time.
3 s
10 s
1
2
Caution!
Make sure the controller is in run mode.
For information about how to exit to run
mode, see section 10.4 Run mode > Exit to
run mode.
To cancel all channel registrations:
1. Press and hold the OK button on the controller until
the LED for channel 1 flashes red/green, or the first
unregistered channel flashes red.
2. Press the < and > buttons simultaneously until the
LEDs for all channels except one turn off (about
10 seconds). The one remaining flashes red.
UK
CZ
DE
DK
EE
ES
FI
FR
HR
HU
IT
LT
LV
NL
NO
PL
PT
RO
RU
SE
SK
68
UPONOR SMATRIX BASE/BASE PRO · INSTALLATION AND OPERATION MANUAL

Table of Contents

Other manuals for Uponor Smatrix Base

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Uponor Smatrix Base and is the answer not in the manual?

Uponor Smatrix Base Specifications

General IconGeneral
BrandUponor
ModelSmatrix Base
CategoryHeating System
LanguageEnglish

Related product manuals