In this menu a time period can be set well in advance
for when away on holiday. When activated, the timer
attempts to reduce the system energy need by setting a
different setpoint temperature for the system.
To change this setting:
1. Press OK to enter parameter edit mode.
2. Use buttons - or + to set the number of days away.
Default: 0d (day)
Setting range: 1 – 44d (days)
3. Press OK to confirm number of days. The
temperature setting starts flashing.
4. Use buttons - or + to adjust the setpoint
temperature during the previously set time period
(holiday).
Default: 17 ˚C
Setting range: 5 – 35 ˚C, 0.5 ˚C increments
5. Press OK to confirm change and to return to the
settings menu.
02 autoBalanCi ng aCtivation
In this menu autobalacing can be activated for the
system.
To change this setting:
1. Press OK to enter parameter edit mode.
2. Use buttons - or + to activate/deactivate.
on = Activated (default)
OFF = Deactivated
3. Press OK to confirm the change and return to the
settings menu.
03 eCo mo de set BaCK temPerature
In this menu the ECO mode setback temperature for the
analogue thermostats is set.
The setting changes the current setpoints (lowers in
heating, and raises in cooling, with the set value) on the
thermostats, when the system is set to ECO mode.
To change this setting:
1. Press OK to enter parameter edit mode.
2. Use buttons - or + to change the parameter.
Default: 4 ˚C
Setting range: 0 – 11 ˚C, 0.5 ˚C increments
3. Press OK to confirm change and to return to the
settings menu.
In this menu temperature display unit is set.
To change this setting:
1. Press OK to enter parameter edit mode.
2. Use buttons - or + to toggle between Celsius and
Fahrenheit.
DEg ˚C – degrees Celsius
DEg ˚F – degrees Fahrenheit
3. Press OK to confirm change and to return to the
settings menu.