35
NO SOFT STOP
DS1 Switch Sengs Gate 1 only (No so stop)
Switch 3 (Gate 1 enable) ON
DS1 Switch Sengs Gate 2 only (No so stop)
Switch 4 (Gate 2 enable) ON
DS1 Switch Sengs Gate 1 & Gate 2 only (No so stop)
Switch 3 & 4 ON
SOFT STOP FOR RETRACT AND EXTEND ARE ON
DS1 Switch Sengs Gate 1 only (So stop for retract and extend are ON)
Switch 3 (Gate 1 enable) ON
Switch 6 (So stop retract enable) ON
Switch 7 (So stop retract enable) ON
DS1 Switch Sengs Gate 2 only (So stop for retract and extend are ON)
Switch 4 (Gate 2 enable) ON
Switch 6 (So stop retract enable) ON
Switch 7 (So stop retract enable) ON
DS1 Switch Sengs Gate 1 & Gate 2 only (So stop for retract and extend are ON)
Switch 3 & 4 ON
Switch 6 (So stop retract enable) ON
Switch 7 (So stop retract enable) ON
Locate the Open / Close command button on the Patriot control board. This button will start the gate
when pressed once; pressing it again will stop the gate.
Press and release the Open / Close button. The linear actuator should begin to extend.
Allow the gate to travel to the factory adjusted extend position. The gate should typically stop short of
the desired extended position.
Press and release the Open / Close button again. The linear actuator should begin to retract.
Allow the gate to travel to the factory adjusted retract position. The gate should typically be very close
to the desired retracted position.