ENGLISH
- 42 -
PARAMETER VALUE DESCRIPTION DEFAULT MEMO
St.AP
Start command during the opening phase
ThismenuallowsxingthecontrolunitconductincaseitreceivesaStart
commandduringtheopeningphase
PAUS
PAUS
Thegatestopsandgoestopause
ChiU
Thegateimmediatelystartsclosing
no
Thegategoonwiththeopeningphase(commandisignored)
St.Ch
Start command during the closing phase
ThismenuallowsxingthecontrolunitconductincaseitreceivesaStart
commandduringtheclosingphase
StoP
StoP
Thegatestopsanditscycleisconsideredasnished
APEr
Thegateopensagain
St.PA
Start command during the pause
ThismenuallowsxingthecontrolunitconductincaseitreceivesaStart
commandwhenthegateisopenduringitspausephase
ChiU
ChiU
Thegatestartsclosing
no
Commandisignored
PAUS
The pause time is reset (Ch.AU)
SPAP
Pedestrian Start during the partial opening phase
Thismenuallowsxingthecontrolunitconductincaseitreceivesa
PedestrianStartcommandduringthepartialopeningphase.
m WARNING: aStartcommandinanyphaseofpartialopeningwill
causethetotalopening;theStartPedestriancommandisalwaysignored
duringatotalopening.
PAUS
PAUS
Thegatestopsandgoestopause
ChiU
Thegateimmediatelystartsclosing
no
Thegategoesonwiththeopeningphase(commandisignored)
Ch.AU
Automatic closing
no
no
Function deactivated
0.5” - 20.0’
Thegateclosesafterthesetuptime
Ch.tr
Closing after transit
Thisfunctionallowshavingafastclosingassoonastransitthroughthe
gateiscompleted,therefore,atimeshorterthanCh.AU isgenerallyused
no
no
Functiondeactivated.Thegateclosesafterthetimesetforthe
functionCh.AU
0.5” - 20.0’
Thegateclosesafterthesetuptime
PA.tr
Pause after transit
Perrendereminimoiltempoincuiilcancellorimaneaperto,èpossibile
fareinmodocheilcancellosiferminonappenavienerilevatoilpassaggio
davantiallefotocellule.Seabilitatoilfunzionamentoautomatico,come
tempo di pausa viene caricato il valore Ch.tr
no
no
Function deactivated
Si
Function activated