- 43 -
PARAMETER VALUE DESCRIPTION DEFAULT MEMO
LUCi
Courtesy lights
Thismenuallowssettingtheautomaticoperatingofthecourtesylights
duringtheopeningcycleofthegate.
CiCL
t .LUC
Timedoperation(from0to20min)
no
Function disabled
CiCL
Onfortheentirecycleduration
AUS
Auxiliary channel
Thismenuallowssettingtheoperatingoftherelayofthelightingofthe
courtesylightsbymeansofaremotecontrolstoredonthechannel4of
the receiver.
Mon
t iM
Timedoperation(from0to20s)
biSt
Bistable operation
Mon
Monostable operation
SPiA
Low voltage output setup
Thismenuallowsyoutosettheoperationofthelowvoltageoutput.
no
no
Not used
FLSh
Flasheroperation(xedfrequency)
W.L.
Indicatorlightoperation:Indicatesthestatusofthegateinreal-time.
Thetypeofblinkingindicatesthefourpossibleconditions:
-GATESTOPPED:Lightoff
-GATEINPAUSE:thelightison,xed
-GATEOPENING:thelightblinksslowly(2Hz)
-GATECLOSING:thelightblinksquickly(4Hz)
LP.PA
Blinker during pause time
no
no
Function deactivated
Si
Blinkerwillbeonduringthepausetimetoo
Strt
Activation inputs (START and START P.)
Thismenuallowsselectinginputoperationmodes(seechapter5.3)
StAn
StAn
Standard mode
no
Startinputsfromterminalboardaredisabled.
Radio inputs operate in standard mode StAn
AP.Ch
Open/Close command
PrES
Dead man operation
oroL
Timer mode
StoP
Stop Input
no
no
TheinputSTOPisnotavailable(ignoredbythecontrolunit)
ProS
TheinputSTOPstopsthegate:pressingthecommandSTARTthegate
continues the motion
invE
ThecommandSTOPstopsthegate:atthenextSTARTthegatestarts
movingintheoppositedirection