Table 45: Joystick control parameters
Index Parameter Min Max Unit Default ID Description
P3.3.5.1
Joystick Signal
Selection
0 6 0 451
0 = Not Used
1 = AI1 (0-100%)
2 = AI2 (0-100%)
3 = AI3 (0-100%)
4 = AI4 (0-100%)
5 = AI5 (0-100%)
6 = AI6 (0-100%)
P3.3.5.2 Joystick Dead Zone 0.0 20.0 % 2.0 384
P3.3.5.3 Joystick Sleep Zone 0.0 20.0 % 0.0 385
0 = Not used
P3.3.5.4 Joystick Sleep Delay 0.00 300.00 s 0.00 386
0 = Not used
Table 46: Jogging parameters
Index Parameter Min Max Unit Default ID Description
P3.3.6.1 Enable DI Jogging Varies Varies
DigIN
Slot0.1
532
P3.3.6.2
Jogging Reference 1
Activation
Varies Varies
DigIN
Slot0.1
530
P3.3.6.3
Jogging Reference 2
Activation
Varies Varies
DigIN
Slot0.1
531
P3.3.6.4 Jogging Reference 1 -MaxRef MaxRef Hz 0.00 1239
P3.3.6.5 Jogging Reference 2 -MaxRef MaxRef Hz 0.00 1240
P3.3.6.6 Jogging Ramp 0.1 300.0 s 10.0 1257
* = The selection of the application with parameter P1.2 Application gives the default value.
See the default values in Chapter 12 Appendix 1.