5.8 GROUP 3.8: SUPERVISIONS
Table 64: Supervision settings
Index Parameter Min Max Unit Default ID Description
P3.8.1
Supervision #1 Item
Selection
0 17 0 1431
0 = Output frequency
1 = Frequency reference
2 = Motor current
3 = Motor torque
4 = Motor power
5 = DC-link voltage
6 = Analogue input 1
7 = Analogue input 2
8 = Analogue input 3
9 = Analogue input 4
10 = Analogue input 5
11 = Analogue input 6
12 = Temperature input 1
13 = Temperature input 2
14 = Temperature input 3
15 = Temperature input 4
16 = Temperature input 5
17 = Temperature input 6
P3.8.2
Supervision #1 Mode 0 2 0 1432
0 = Not used
1 = Low limit supervision
2 = High limit supervision
P3.8.3 Supervision #1 Limit -50.00 50.00 Varies 25.00 1433
P3.8.4
Supervision #1 Limit
Hysteresis
0.00 50.00 Varies 5.00 1434
P3.8.5
Supervision #2 Item
Selection
0 17 1 1435
See P3.8.1
P3.8.6 Supervision #2 Mode 0 2 0 1436 See P3.8.2
P3.8.7 Supervision #2 Limit -50.00 50.00 Varies 40.00 1437
P3.8.8
Supervision #2 Limit
Hysteresis
0.00 50.00 Varies 5.00 1438
PARAMETERS MENU VACON · 129