5.5 GROUP 3.5: I/O CONFIGURATION
Table 52: Digital input settings
Index Parameter Min Max Unit Default ID Description
P3.5.1.1 Control Signal 1 A
DigIN
SlotA.1 *
403
P3.5.1.2 Control Signal 2 A
DigIN
SlotA.2 *
404
P3.5.1.3 Control Signal 3 A
DigIN
Slot0.1
434
P3.5.1.4 Control Signal 1 B
DigIN
Slot0.1 *
423
P3.5.1.5 Control Signal 2 B
DigIN
Slot0.1 *
424
P3.5.1.6 Control Signal 3 B
DigIN
Slot0.1
435
P3.5.1.7 I/O B Control Force
DigIN
Slot0.1 *
425
CLOSED = Force the
control place to I/O B.
P3.5.1.8
I/O B Reference
Force
DigIN
Slot0.1 *
343
CLOSED = I/O refer-
ence B (P3.3.1.6) gives
the frequency refer-
ence.
P3.5.1.9
Fieldbus Control
Force
DigIN
Slot0.1 *
411
P3.5.1.10
Keypad Control
Force
DigIN
Slot0.1 *
410
P3.5.1.11 External Fault Close
DigIN
SlotA.3 *
405
OPEN = OK
CLOSED = External
fault
P3.5.1.12 External Fault Open
DigIN
Slot0.2
406
OPEN = External fault
CLOSED = OK
P3.5.1.13 Fault Reset Close Varies 414
CLOSED = Resets all
active faults.
P3.5.1.14 Fault Reset Open
DigIN
Slot0.1
213
OPEN = Resets all
active faults.
P3.5.1.15 Run Enable
DigIN
Slot0.2
407
PARAMETERS MENU VACON · 115