Table 113: The basic I/O parameters in the I/O and Hardware menu
Index Parameter Min Max Unit Default ID Description
V5.1.1 Digital Input 1 0 1 0 2502
Status of the digital
input signal
V5.1.2 Digital Input 2 0 1 0 2503
Status of the digital
input signal
V5.1.3 Digital Input 3 0 1 0 2504
Status of the digital
input signal
V5.1.4 Digital Input 4 0 1 0 2505
Status of the digital
input signal
V5.1.5 Digital Input 5 0 1 0 2506
Status of the digital
input signal
V5.1.6 Digital Input 6 0 1 0 2507
Status of the digital
input signal
V5.1.7
Analogue Input 1
Mode
1 3 3 2508
Shows the mode that is
set for the analogue
input signal. The selec-
tion is made with a DIP
switch on the control
board.
1 = 0...20mA
3 = 0...10V
V5.1.8 Analogue Input 1 0 100 % 0.00 2509
Status of the analogue
input signal
V5.1.9
Analogue Input 2
Mode
1 3 3 2510
Shows the mode that is
set for the analogue
input signal. The selec-
tion is made with a DIP
switch on the control
board.
1 = 0...20mA
3 = 0...10V
V5.1.10 Analogue Input 2 0 100 % 0.00 2511
Status of the analogue
input signal
VACON · 168 I/O AND HARDWARE MENU