Table 128: The default values of parameters in the different applications
Index Parameter Default Unit ID Description
A B C D E F
3.2.1 Rem Control
Place
0 0 0 0 0 0 172 0 = I/O Control
3.2.2 Local/Remote 0 0 0 0 0 0 211 0 = Remote
3.2.6 I/O A Logic 2 2 2 2 2 2 300 2 = Forw-Back (edge)
3.2.7 I/O B Logic 2 2 2 2 2 2 363 2 = Forw-Back (edge)
3.3.1.5 I/O A Ref Sel 6 5 6 7 6 8 117
5 = AI2
6 = AI1 + AI2
7 = PID
8 = Motor Potentiometer
3.3.1.6 I/O B Ref Sel 4 4 4 4 4 4 131 4 = AI1
3.3.1.7 Keypad Ref Sel 2 2 2 2 2 2 121 2 = Keypad Reference
3.3.1.10 Fieldbus Ref
Sel
3 3 3 3 3 3 122 3 = Fieldbus Reference
3.3.2.1 Torque Ref Sel 0 0 0 0 4 0 641
0 = Not Used
4 = AI2
3.3.3.1 Preset Freq
Mode
- - 0 0 0 0 182 0 = Binary Coded
3.3.3.3 Preset Freq 1 - - 10.0 10.0 5.0 10.0 105
3.3.3.4 Preset Freq 2 - - 15.0 - - - Hz 106
3.3.3.5 Preset Freq 3 - - 20.0 - - - Hz 126
3.3.3.6 Preset Freq 4 - - 25.0 - - - Hz 127
3.3.3.7 Preset Freq 5 - - 30.0 - - - Hz 128
3.3.3.8 Preset Freq 6 - - 40.0 - - - Hz 129
3.3.3.9 Preset Freq 7 - - 50.0 - - - Hz 130
3.5.1.1 Ctrl Signal 1 A 100 100 100 100 100 100 403 100 = DigIN SlotA.1