Vacon 100 INDUSTRIAL - Page 40

Vacon 100 INDUSTRIAL
360 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
6
2
3
4
5
18
19
30
12
7
13
8
9
10
14
15
16
21
22
23
11
17
A
B
24
25
26
32
33
Modbus RTU,
N2, BACnet
28
29
(0)4...20mA
+
-
*)
**)
mA
FAULT
RUN
RUN
AO1-/GND
+24 Vin
24
V
out
GND
GND
DI1
DI2
DI3
DI4
DI5
DI6
R O1/1 NC
R O1/2 CM
R O1/3 NO
CM
CM
RS485
RS485
R O2/1 NC
R O2/2 CM
R O2/3 NO
R O3/2 CM
R O3/3 NO
Standard I/O board
Terminal Signal Description
+10Vref
AI1+
AI1-
AI2+
AI2-
24Vout
Reference output
Analogue input 1 +
Analogue input 1 -
Analogue input 2 +
Analogue input 2 -
24V auxiliary voltage
I/O ground
Digital input 1
Digital input 2
Digital input 3
Digital input 4
Digital input 5
Digital input 6
Common for DI1-DI6
Common for DI1-DI6
24V auxiliary voltage
I/O ground
Analogue output 1 +
Analogue output 1 -
24V auxiliary
input voltage
Output
frequency
0...20mA)
READY
Serial bus, negative
Serial bus, positive
Relay output 1
Relay output 2
Relay output 3
FAULT
Fault reset
AO1+
Frequency reference
(default 0...10V)
Frequency reference
(Default 4...20mA)
Start forward
Start reverse
External fault
Ramp 1/Ramp 2 selection
Reference-
potentiom-
eter
1...10kΩ
Preset frequency 1
2-wire
transducer
TI1+
TI1-
Thermistor input
Fig. 12: The default control connections of the Multi-purpose application
* = Available only in VACON
®
100 X.
VACON · 40 QUICK STARTUP GUIDE
1
LOCAL CONTACTS: HTTP://DRIVES.DANFOSS.COM/DANFOSS-DRIVES/LOCAL-CONTACTS/