Parameters vacon • 137
Local contacts: https://www.danfoss.com/en/contact-us/contacts-list/
7.1.18 Group 3.22: Solar
7.1.18.1 Group 3.22.1: Start Settings
7.1.18.2 Group 3.22.2: MPPT
Table 121. Start Settings parameters
Code Parameter Min Max Unit Default ID Description
P3.22.1.1 Start DC Voltage
P3.22.
2.16+
5 V
1100 V Varies 1916
DV voltage threshold level to activate
Run enable.
P3.22.1.2 Short restart delay 0.1 5.0 m 1.0 1917 Delay time to restart
P3.22.1.3 Short restart delay tries 1 10 5 1918 Number of restart tries
P3.22.1.4 Long restart delay 6.0 30.0 m 10.0 1919 Long delay time to restart
P3.22.1.5 Sleep in solar mode
Dis-
abled
Enable
d
Dis-
abled
1964
0 = Sleep disabled
1 = Sleep according to P3.13.5.1 and
P3.13.5.2
NOTE!
Sleep in solar mode can be managed according to P3.13.5.1 and P3.13.5.2
When P3.22.1.5 = 1, the drive will stop if the output frequency is below the value in P3.13.5.1, for
the time in P3.13.5.2. It will restart as after a stop due to low power.
Sleep function allows to program a minimum frequency P3.3.1.1 that is below the efficient range
of the pump. MPPT can reach this low value, leading to a minimum output power and avoiding to
stop the drive in case of temporary reduced irradiation. If the condition persists, sleep logic will
then stop the drive.
Table 122. MPPT parameters
Code Parameter Min Max Unit Default ID Description
P3.22.2.1 Vmp at 100% power
P3.22.2.16
+ 5 V
1100 V Varies 1920
P3.22.2.2 Vmp at 10% power
P3.22.2.16
+ 5 V
1100 V Varies 1921
P3.22.2.3
Panel/Motor power
ratio
50.00 100.00 % 100.00 1922
P3.22.2.4 P gain 0.000 1.000 0.050 1923
Gain for internal PI regulator.
The internal frequency refer-
ence keeps the panels working
on MPP.
P3.22.2.5 I gain 0.000 1.000 0.050 1924 Integration time.
P3.22.2.6 Acceleration time 0.1 60.0 s 1.0 1925
Time from minimum to maxi-
mum frequency
P3.22.2.7 Deceleration time 0.1 60.0 s 1.0 1926
Time from maximum to mini-
mum frequency
P3.22.2.8 P&O update time 2 6 s 3 1939
P3.22.2.9 P&O voltage step 3 10 V 5 1940
P3.22.2.10 P&O power variation 0.2 5.0 % 1.0 1941
P3.22.2.11
P&O local max volt
step
20 60 V 30 1945