1. PREFACE
The VACON
®
AC drive contains a preloaded VACON
®
100 Solar Pump application for instant use.
1.1 Specific functions of VACON
®
Solar pump application
The VACON
®
100 Solar Pump application allows flexible use of VACON
®
100 frequency converters.
This dedicated application software was developed to drive a solar pump with an optimized MPPT
(Maximum Power Point Tracking) for VACON
®
100 supplied by solar panels.
The MPPT is based on 4 parallel algorithms:
Feed-Forward Controller (to follow the radiation variations)
Correction Controller (to compensate the temperature variations)
Oscillation Damping Regulator (to prevent the panel entering in the “current source” branch
of the characteristic)
Local Maxima logic (to prevent the regulator from being trapped in a local maximum lower
than absolute maximum)
Features
The MPP Tracker controls DC voltage reference in order to find the maximum power.
Extensive wizards for start-up, PID-control used to facilitate commissioning
‘Funct’ button for easy change between Local (keypad) and Remote control place. The
remote control place is selectable by parameter (I/O or Fieldbus)
8 preset frequencies
Motor potentiometer functions
•2 programmable ramp times, 2 supervisions and 3 ranges of prohibited frequencies
Control page for easy operation and monitoring of the most essential values.
Fieldbus data mapping
•Automatic reset
•Different pre-heat modes used to avoid condensation problems
Maximum output frequency 320 Hz
Real-time clock and timer functions available (optional battery required). Possible to pro-
gram 3 time channels to achieve different functions on the drive (e.g. Start/Stop and Preset
frequencies)
External PID-controller available. Can be used to control e.g. a valve using the AC drive I/O
Sleep mode function which automatically enables and disables drive running with user
defined levels to save energy.
2-zone PID-controller (2 different feedback signals; minimum and maximum control)
Two setpoint sources for the PID-control. Selectable with digital input
PID setpoint boost function
Feedforward function to improve the response to the process changes
Process value supervision
Maintenance counter
Underload protection can be managed by measuring Motor torque (standard sensorless
mode) or by measuring the water flow with a flow meter sensor. This sensor can be an ana-
logue signal or a digital input. With this sensor it is possible to measure the water flow
[litres/min] and the total volume of the water flow [m
3
].
Sleep mode can be enabled or disabled with a parameter.
Digital inputs can be used to measure water levels (minimum and maximum).