3
vacon • 66 Descriptions of VACON® option boards
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
Jumper selections
On the OPTBB board, there is one jumper block used to program the control voltage (auxiliary
voltage). The factory default and other available jumper selections are presented below.
NOTE! It is recommended to use a +12 or +15 supply voltage instead of 5 V.
This is because our interface does not support "sense" function to compensate voltage drop which
results in a cable length limit of about 60 m with 0.5 mm
2
wire section for the supply. The problem
does not exist with 12 or 15 v supply.
If 5V is used, it is recommended to use two or more wires in parallel for supply connection.
5V
12V
15V
5V
12V
15V
5V
12V
15V
Jumpe
r
block
X
11
Auxiliary voltage level
=
Fa c to r y d e f a ul t
7283.emf

Other manuals for Vacon NXP series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vacon NXP series and is the answer not in the manual?

Vacon NXP series Specifications

General IconGeneral
Communication interfacesRS-485, Ethernet
Storage temperature range-40°C to +70°C
DimensionsVaries by model
WeightVaries by model
Product seriesNXP
Voltage range200 V to 690 V
Input voltage range200 V to 690 V
Frequency range0 Hz to 500 Hz
Control methodVector control
Protection featuresOvercurrent, overvoltage, undervoltage, overtemperature, short circuit
Enclosure classesIP21, IP54
Braking chopperBuilt-in or external
EMC filterBuilt-in or external
Communication protocolsModbus, Profibus, CANopen, Ethernet
Operating temperature range-10°C to +50°C
Humidity range5% to 95% (non-condensing)
Cooling methodAir-cooled or liquid-cooled