HMDW80 Series Transmitter Models
Table 3 below lists the most important differences between the HMDW80
series transmitter models. For technical specifications, see Chapter 6, Technical
Data, on page 43.
Table 3 HMDW80 Series Transmitter Models
Model
Type
Outputs
Display
IP Rating
Output
Parameters
HMD82
Duct
2 × 4 ... 20 mA
No
IP65
T, RH, Td, h, Tw
HMD82D
Duct
2 × 4 ... 20 mA
Yes
IP65
T, RH, Td, h, Tw
TMD82
Duct
1 × 4 ... 20 mA
No
IP65
T
HMD83
Duct
2 × 0 ... 10 V
No
IP65
T, RH, Td, h, Tw
HMD83D
Duct
2 × 0 ... 10 V
Yes
IP65
T, RH, Td, h, Tw
TMD83
Duct
1 × 0 ... 10 V
No
IP65
T
HMW82
Wall
2 × 4 ... 20 mA
No
IP30
T, RH
HMW82P100
Wall
2 x 4 … 20 mA
No
IP30
T, RH
TMW82
Wall
1 × 4 ... 20 mA
No
IP30
T
HMW83
Wall
2 × 0 ... 10 V
No
IP30
T, RH
TMW83
Wall
1 × 0 ... 10 V
No
IP30
T
HMW88
Wall
2 × 4 ... 20 mA
No
IP65
T, RH, Td, h, Tw
HMW88D
Wall
2 × 4 ... 20 mA
Yes
IP65
T, RH, Td, h, Tw
HMW89
Wall
2 × 0 ... 10 V
No
IP65
T, RH, Td, h, Tw
TMW88
Wall
1 x 4 … 20 mA
No
IP65
T
HMW89D
Wall
2 × 0 ... 10 V
Yes
IP65
T, RH, Td, h, Tw
HMS82
Outdoor
2 × 4 ... 20 mA
No
IP65
T, RH, Td, h, Tw
HMS83
Outdoor
2 × 0 ... 10 V
No
IP65
T, RH, Td, h, Tw
TMS82
Outdoor
1 x 4 … 20 mA
No
IP65
T
Output Parameters Explained
Table 4 Parameters Supported by HMDW80 Series
Parameter
Symbol
Unit(s)
Description
Temperature
T
°C
°F
Temperature in Celsius or Fahrenheit scale.
Relative
humidity
RH
%
Ratio of the partial pressure of water vapor in
the air to the saturation vapor pressure of air
at the current temperature.
Dewpoint
Td
°C
°F
Temperature at which the water vapor in the air
will condense into water at the current pressure.
When the dewpoint is below 0 °C, the
transmitter outputs frostpoint (Tf) instead of
dewpoint.
Enthalpy
h
kJ/kg
BTU/lb
Sum of the internal energy of a thermodynamic
system.
Wet bulb
temperature
Tw
°C
°F
The minimum temperature that can be reached
by evaporative cooling in the current conditions.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaisala INTERCAP HMDW80 Series and is the answer not in the manual?

Vaisala INTERCAP HMDW80 Series Specifications

General IconGeneral
BrandVaisala
ModelINTERCAP HMDW80 Series
CategoryTransmitter
LanguageEnglish

Related product manuals