Installation, Operating & Maintenance Instructions
Series 650 DN 100-250 (I.D. 4“ - 10”), CC-Link
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com
280672EB
2010-12-15
23/94
2.6.7.4 Install CC-Link cable at valve controller
Description Required tool
3. Remove the cable coat carefully
Cable Pos. A, x about 30mm
Cable Pos. B, x about 40mm
Note: Pos. see step 8
Knife
4. Cut off the shield wire
Side-cutting pliers
5. Cut off the aluminum shield and remove it
Side-cutting pliers
6. Cut off the plastic and remove it
Note:
Take care to the wires. Do not damage the
isolation of wires!
Side-cutting pliers
7. Cut off the shield wires about 15mm
8. Separate the shield wires in two equal
quantum and place them 180° opposite
Side-cutting pliers
15mm
x