Installation, Operating & Maintenance Instructions 
Series 650 DN 100-250 (I.D. 4“ - 10”), CC-Link 
 
 
 
VAT Vakuumventile AG, CH-9469 Haag, Switzerland 
Tel +41 81 771 61 61   Fax +41 81 771 48 30   CH@vatvalve.com www.vatvalve.com 
280672EB 
2010-12-15 
23/94 
 
2.6.7.4  Install CC-Link cable at valve controller 
 
Description  Required tool 
3.  Remove the cable coat carefully 
 Cable Pos. A, x about 30mm 
 Cable Pos. B, x about 40mm 
Note: Pos. see step 8 
 
Knife 
4.  Cut off the shield wire 
 
Side-cutting pliers 
5.  Cut off the aluminum shield and remove it 
 
Side-cutting pliers 
6.  Cut off the plastic and remove it 
 
Note: 
Take care to the wires. Do not damage the 
isolation of wires! 
Side-cutting pliers 
7.  Cut off the shield wires about 15mm 
 
8.  Separate the shield wires in two equal 
quantum and place them 180° opposite 
 
Side-cutting pliers 
15mm 
x