DSGH Installation and Operation Guide 85
Diagnostics and repair
HV Sensor high
voltage
ONhigh
voltage is
within
specification
OFFhigh
voltage is
outside of
specification
Call VEGA Field
Service
Field Radiation
field
indicator
Cycles in
proportion to
radiation field
intensity at
detector. ON
for 10 seconds
for each mR/hr,
then off for 2
seconds.
(Can use LED
5 that blinks 1
time/sec to
time LED1 for
field indicator.)
None
Check for closed
source shutter,
buildup, and
insulation.
Table 5.8
CPU board LED summary
LED Description
Normal
condition
Error
condition Recommendation