A - 4
Enclosure A - Electrode Humidier
Liebert
®
PDX, EconoPhase Version - UM - 265133 - 29.08.2019
reach the stage where they also stick to the inside wall of the cylinder; in the event of especially conductive deposits, the consequent
heat produced may overheat the plastic and melt it, and, in more severe cases,puncture the cylinder, allowing water to leak back
into the tank.
As a precaution, check, at the frequency recommended further on, for deposits and the blackening of the wall of the cylinder, and replace
the cylinder if necessary.
Warning: always disconnect the appliance before touching the cylinder in the event of leaks, as current may be running through the water.
A.4.4 - Replacement and maintenance of other components
Fill solenoid valve: after having disconnected the cables and the tubing, remove the solenoid valve and check the condition of the inlet
lter; clean if necessary using water and a soft brush.
Supply and drain manifold: check that there are no solid residues in the cylinder attachment, remove any impurities. Check that the gasket
(O- ring) is not damaged or cracked; if necessary, replace it.
Drain pump: disconnect the power supply, remove motor body unscrew the fastening three screws; remove any impurities and rinse.
Supply tank & conductivity meter : check that there are no obstructions or solid particles and that the electrodes for measuring the
conductivity are clean, remove any impurities and rinse.
Hose kit: check that the hoses are free and do not contain impurities; remove any impurities and rinse.