OF THE TUBE. IN THIS CASE, THE TENDENCY IS TO OB-
TAIN A REDUCED FUEL FLOW RATE. THE SUCTION OUT-
LET ON THE MANIFOLD HAS A SECTION INTENTIONALLY
REDUCED FOR THE PURPOSE OF ENHANCING THE SUC-
TION PULSATION AND THEREBY GUARANTEE A CON-
STANT TAP FLOW RATE.
Specific tooling
020329Y Mity-Vac vacuum-operated pump
Characteristic
Minimum flow rate
20 cc
- Completely empty the fuel tank.
- Remove the petrol delivery pipe and the low-
pressure pipe.
- Loosen the clip and remove the cock.
- Clean the tank and the filter of the cock with a
specific solvent.
- Refit the cock making sure that there is an O-
Ring.
- Turn the cock to the direction it had before it was
removed and block the clip.
N.B.
THE FILTER CAN BE UNSCREWED FROM THE COCK TO
FACILITATE CLEANING.