EasyManua.ls Logo

Vetus EC4 - System Configuration in Case of Options; Commissioning of Actuators for Installations with Trim or Flap Command Option; Commissioning of Actuators for Installations with Trolling Option; Commissioning of the Actuators with Neutral Relay Option

Vetus EC4
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
030624.13 73
vetus® Electronic engine remote control
15 System configuration in case of options
15.1 Commissioning of actuators for installations with Trim or Flap command option
Trim or flap options dont require any programming on the actuator.
Trim and flap cables are reported from section 6.4 to section to 6.5 included.
Sections 5.3.2 and 5.3.3 depict the pin-out of the electronic PCBs which perform the trim/flap commands. Electrical in-
stallation schemes are at sections 8.2.7 and 8.2.8.
15.2 Commissioning of actuators for installations with Trolling option
The command station must be configured by setting dip-switch 2 to ON (see section 4.5 of this manual). The actuator
is specific for this type of system. For its programming, refer to the document Trolling_Flap option for lever EC3 & EC4”.
15.3 Commissioning of the actuators with Neutral Relay option
The mechanical actuator can provide a no contact signal when the gearbox is in neutral. This signal, if properly used in
the engine starter safety chain, allows the start of the propulsion engine only in case the gearbox is in neutral position.
The neutral signal is given through a two pole wire, as depicted here below. The neutral relay is normally open and it clos-
es only in case the gearbox is in neutral and the actuator is properly supplied (if the actuator doesnt receive the power
supply the relay is switched off and its contact is open).
The block diagram here below shows the safety chain:
+
-
R
+
-
Function Wire number
Forward (FWD) - Signal 1
Reverse (REV) - Signal 2
Neutral relay 3
Forward (FWD) - GND 4
Neutral relay 5
Reverse (REV) - GND 6
Engine ignition key
Electrical engine
starter activation circuit
Battery
Starter
Specific neutral cable is described at section 6.3

Table of Contents

Other manuals for Vetus EC4

Related product manuals