52
6 Maintenance
Checking and cleaning the raw water strainer
Daily, before starting.
9 Checking the raw water strainer
Check daily whether there is any dirt in the
raw water strainer.
10 Cleaning the strainer
Close the seacock before removing the lid
of the water strainer.
Clean the raw water strainer as often as is
necessary, depending on the pollution of
the waterways, but at least once every 6
months. A clogged raw water strainer will
result in excessive temperatures or over-
heating of the engine coolant.
Check the sealing between the lid and
housing after cleaning and re-assembling
the strainer. An improperly sealed lid will re-
sult in air sucked in by the sea water pump
which again will result in overheating of the
engine.
VD00802
VD00801
note
Only engines with intercooling!