M2
M3
M4
55
6 Maintenance
Draining of water from the water separator/fuel lter
Every 100 operating hours.
A second bleeding nipple is located at the fuel
injection pump.
Close the bleeding nipples when all air has
escaped.
Operate the starter switch until the engine
res; release the starter switch if the engine
does not re within 20 seconds.
Wait until the starter motor has stopped
before making a new attempt to start the
engine.
Repeat the above if the engine cuts out af-
ter a short time.
VD02029
VD02028
VD00109
1410
2112
14 Start the engine

Table of Contents