Type AWO-M/AWO-M-E/AWO-M-E-AC 201.A04 201.A06 201.A08 201.A10 201.A13 201.A16
Indoor unit electrical values
Heat pump control unit/PCB
– Rated voltage, control unit/PCB 1/N/PE 230 V/50 Hz
– Power supply fuse rating 1 x B16A 1 x B16 A 1 x B16 A 1 x B16 A 1 x B16 A 1 x B16 A
– Internal fuse 6.3 A (slow)/250 V
Instantaneous heating water heater
– Type AWO-M-E/AWO-M-E-AC: Facto-
ry-fitted
– Type AWO-M: Accessories
– Rated voltage 1/N/PE 230 V/50 Hz
or
3/N/PE 400 V/50 Hz
– Heating output kW 9 9 9 9 9 9
– Power supply fuse rating 3 x B16A 3 x B16 A 3 x B16 A 3 x B16 A 3 x B16 A 3 x B16 A
Max. power consumption
Fan W 45 45 115 2 x 115 2 x 115 2 x 115
Outdoor unit kW 2.85 3.20 3.30 4.55 5.08 5.08
Secondary pump (PWM) W 60 60 60 60 60 60
– Energy efficiency index EEI ≤ 0.2 ≤ 0.2 ≤ 0.2 ≤ 0.2 ≤ 0.2 ≤ 0.2
Control unit/PCB, outdoor unit W 15 15 15 15 15 15
Control unit/PCB, indoor unit W 10 10 10 10 10 10
Control unit/PCB power, indoor unit W 1000 1000 1000 1000 1000 1000
Refrigerant circuit
Refrigerant R410A R410A R410A R410A R410A R410A
– Refrigerant charge kg 1.40 1.40 1.40 2.40 2.40 2.40
–
Global warming potential (GWP)
*1
1924 1924 1924 1924 1924 1924
– CO
2
equivalent t 2.7 2.7 2.7 4.6 4.6 4.6
Compressor (hermetically sealed) Type Scroll Scroll Scroll Scroll Scroll Scroll
– Oil in compressor Type 3 MAF POE 3 MAF POE 3 MAF POE 3 MAF POE 3 MAF POE 3 MAF POE
– Quantity of oil in compressor l 0.76 0.76 0.76 1.17 1.17 1.17
Permissible operating pressure
– High pressure side bar 43 43 43 43 43 43
MPa 4.3 4.3 4.3 4.3 4.3 4.3
– Low pressure side bar 28 28 28 28 28 28
MPa 2.8 2.8 2.8 2.8 2.8 2.8
Outdoor unit dimensions
Total length mm 546 546 546 546 546 546
Total width mm 1109 1109 1109 1109 1109 1109
Total height mm 753 753 753 1377 1377 1377
Indoor unit dimensions
Total length mm 370 370 370 370 370 370
Total width mm 450 450 450 450 450 450
Total height mm 880 880 880 880 880 880
Total weight
Outdoor unit kg 102 102 103 145 145 145
Indoor unit
– Type AWO-M kg 40 40 40 40 40 40
– Type AWO-M-E/AWO-M-E-AC kg 41 41 41 41 41 41
Permissible operating pressure, sec-
ondary side
bar 3 3 3 3 3 3
MPa 0.3 0.3 0.3 0.3 0.3 0.3
Connections (female thread)
Heating water flow G 1¼ 1¼ 1¼ 1¼ 1¼ 1¼
Heating water return and DHW cylinder
return
G 1¼ 1¼ 1¼ 1¼ 1¼ 1¼
DHW cylinder flow G 1¼ 1¼ 1¼ 1¼ 1¼ 1¼
Secondary circuit flow G 1¼ 1¼ 1¼ 1¼ 1¼ 1¼
Secondary circuit return G 1¼ 1¼ 1¼ 1¼ 1¼ 1¼
Length of connection line between in-
door and outdoor units (Hydraulic con-
nection set)
m 1 to 20 1 to 20 1 to 20 1 to 20 1 to 20 1 to 20
Sound power of outdoor unit at rated heating output
(Measurements with reference to EN 12102/
EN ISO 9614-2)
Weighted total sound power level
–
At A7
±3 K
/W55
±5 K
(max.)
dB(A) 56 56 58 60 61 61
–
At A7
±3 K
/W55
±5 K
in night mode
dB(A) 50 50 50 55 55 55
*1
Based on the Fifth Assessment Report of the Intergovernmental Panel on Climate Change (IPCC)
Vitocal 200-A
(cont.)
10
VIESMANN
VITOCAL
2
5831388