Type AWO-M/AWO-M-E/AWO-M-E-AC 201.A04 201.A06 201.A08 201.A10 201.A13 201.A16
Energy efficiency class to EU Regula-
tion no. 813/2013
Heating, average climatic conditions
Low temperature applications (W35)
A
++
A
++
A
+++*2
A
+++*2
A
+++*2
A
+++*2
Medium temperature applications
(W55)
A
+
A
++
A
++
A
++
A
++
A
++
Performance data as per EU Regulation
no. 813/2013 (average climatic condi-
tions)
Low temperature applications (W35)
Energy efficiency η
S
% 173 172 175 176 175 175
Rated heating output P
rated
kW 5.38 5.59 6.82 9.32 9.99 10.61
Seasonal coefficient of performance
(SCOP)
4.40 4.38 4.46 4.47 4.46 4.46
Medium temperature applications (W55)
Energy efficiency η
S
% 124 125 127 129 130 130
Rated heating output P
rated
kW 5.23 5.59 6.41 9.35 10.07 10.72
Seasonal coefficient of performance
(SCOP)
3.18 3.21 3.25 3.29 3.32 3.34
Sound power level to ErP
Sound power level, outdoor unit dB(A) 53 54 55 56 56 56
Note
Reduced noise night mode can be enabled at the heat pump control
unit at the "Contractor" setting level.
400 V appliances
Type AWO/AWO-E/AWO-E-AC 201.A10 201.A13 201.A16
Heating performance data to EN 14511 (A2/W35)
Rated heating output kW 6.10 6.67 7.02
Fan speed rpm 600 600 600
Power consumption kW 1.49 1.64 1.78
Coefficient of performance ε (COP) in heating mode 4.10 4.06 3.94
Output control kW 4.40 to 10.10 4.80 to 10.70 5.20 to 11.20
Heating performance data to EN 14511 (A7/W35, 5 K spread)
Rated heating output kW 7.58 8.88 10.11
Fan speed rpm 600 600 600
Air flow rate
m
3
/h
4500 4500 4500
Power consumption kW 1.51 1.78 2.04
Coefficient of performance ε (COP) in heating mode 5.01 4.99 4.95
Output control kW 5.45 to 13.60 5.93 to 14.20 6.40 to 14.70
Heating performance data to EN 14511 (A–7/W35)
Rated heating output kW 10.09 11.06 11.60
Power consumption kW 3.17 3.60 3.87
Coefficient of performance ε (COP) in heating mode 3.18 3.07 3.00
Heating performance data to EN 14511 (A35/W7)
Rated cooling capacity kW 5.00 6.00 7.00
Fan speed rpm 600 600 600
Power consumption kW 1.90 2.30 2.80
Energy efficiency ratio EER in cooling mode 2.70 2.60 2.50
Output control kW Up to 8.00 Up to 9.00 Up to 10.00
Heating performance data to EN 14511 (A35/W18)
Rated cooling capacity kW 7.00 8.20 9.20
Fan speed rpm 600 600 600
Power consumption kW 1.71 2.00 2.30
Energy efficiency ratio EER in cooling mode 4.10 4.10 4.00
Output control kW Up to 8.00 Up to 9.00 Up to 10.00
Air intake temperature
Cooling mode (type AWO-E-AC only)
Min. °C 10 10 10
Max. °C 45 45 45
Heating mode
Min. °C –20 –20 –20
Max. °C 35 35 35
*2