ENGLISH - 3
1. Technical Specifications
• Supply voltage:
- 12 V~ 50-60 Hz +25% –15%
- 12 V d.c. +10% –10%
- 24 V~ 50-60 Hz +25% –15%
- 24 V d.c. +10% –10%
• Typical current draw:
- 12 V~ 50-60 Hz: 55 mA
- 12 V d.c.: 45mA
- 24 V~ 50-60 Hz: 80 mA
- 24 V d.c.: 35 mA
• potential-free single changeover relay output 24 V~/24 V
d.c. 8 A cos ø 1 configurable for:
- pulse operation (monostable timer - flash mode): insertion
of the smart card causes the relay contact to close for
about 3 seconds
- latching operation (bistable - toggle mode): insertion of the
smart card causes the relay contact to open/close in a
cyclical sequence
• dip-switches at the rear of the device (figure 1.1) for
1.1
selecting the address and operating mode (see “Dip
switches” and “Address selection” tables on page 6).
• operation as an electronic switch with smart card insertion
causing the relay contact to close; the contact re-opens
when the smart card is removed (choice of immediate
opening, or with 50-second delay).
• Operating temperature range: –5°C - +45 °C.
1
O
N
2 3 4 5 6 7