7.4 Synchronising readers with
MASTER smart cards
The “Synchronise Readers with MASTER smart card” proce-
dure allows several readers to operate using the same MAS-
TER smart card and the same MASTER code.
Synchronising a non-initialised reader
7.4.1
Place dip-switch 2 on the reader being
synchronised in the ON position.
The LED lights up yellow.
7.3.9
To exit the procedure, press the front but-
ton.
The LED blinks yellow 3 times, and then
turns off.
If no smart cards are inserted for about 2 min-
utes, the procedure automatically terminates.
Exiting the procedure is signalled by the LED
blinking yellow 3 times.