TESTING THE SYSTEM
D-307502 PowerMaster-10/30 G2 User's Guide 59
Perform a "Diagnostic test" as explained in the detector's datasheet.
Activate any of the keyfob buttons.
Perform a disarm or arm routine or press any other key that activates the LED.
Follow the "Diagnostic Tests" described in the repeater's datasheet.
In general, follow the "Diagnostic Tests" described in the device's datasheet or
activate any of its functions.
a. Three seconds after the device is displayed, the device LED blinks to assist you to identify ("it's me").
b. To end the session, press the button until the display reads [<OK> TO EXIT] then press .
Periodic Test per Partition
In addition to the regular Periodic Test, you can also test zones for enrolled sensors (excluding temperature
sensors and sirens) that are assigned to a selected partition.
A. To Conduct the Periodic Test per Partition
1
Make sure the selected partition is disarmed and the other partitions are not
in exit or entry delay and then press the partition ( ) button.
When the display reads [SELECT PARTITION], press the partition number of
the zones you wish to test, for example, (Partition 1).
Press the button repeatedly until the display reads [PERIODIC TEST]
and press .
The screen will now prompt you to enter your Master user code.
Enter your Master user code.
2
To enter the devices test procedure per partition, press .
The display reads [NOT ACTIVE NNN]. NNN indicates the number of enrolled
devices in the panel that have not been tested yet. This number automatically
drops one count for every tested device.
Test per partition is performed by activating each device as explained in point
4 in the Additional Information table below.
After a device has been activated, the control panel reads [Zxx IS ACTIVATED]
and the "N" indicator drops one count.
After all devices have been tested, the control panel reads [DEVICE TESTS END].
Additional Information (Periodic Test per Partition)
Partitioning must be enabled by your installer.
If you have not already changed your personal code number, use the default setting – 1111.
To abort, press the button; the display reads [<OK> TO END]. Press the button.
To activate system devices during the "Periodic Test Per Partition"; make sure the device LED lights when
activated: