74 D-307502 PowerMaster-10/30 G2 User's Guide
PowerMaster-10 G2
PowerMaster-30 G2
by GP or p/n LTT-2300AA4Y, manufactured
by LTT. For UL Listed product, use these
batteries only.
Caution! Risk of explosion if battery is
replaced by an incorrect type. Dispose of
used batteries according to the
manufacturer's instructions.
Note: For compliance with CE standards the
battery capacity must be at least 1300 mAh.
hours
32h
no backup
0 mA
10 mA
39h
no backup
no backup
0 mA
(1) The external devices must be connected
between 12V and ground. The current for
each specified backup period can be
drawn from the batteries with the internal
GSM and the proximity reader connected
to the PowerMaster-30 G2.
(2) 7.2V 1300 mAh, rechargeable NiMH
battery pack, p/n 130AAM6BMX,
manufactured by GP or p/n LTT-
AA1300LSDX6B, manufactured by LTT.
(3) 9.6V 1800 mAh, rechargeable NiMH
battery pack, p/n GP180AAH8BMX,
manufactured by GP or p/n LTT-
AA1800LSDX8B, manufactured by LTT.
(4) 9.6V 2200 mAh, rechargeable NiMH
battery pack p/n 220AAH8BMX,
manufactured by GP or p/n LTT-
AA2200LSDX8B, manufactured by LTT.
Caution! Risk of explosion if battery is
replaced by an incorrect type. Dispose of
used batteries according to the
manufacturer's instructions.
Notes:
1. For compliance with CE standards the battery
backup period must be at least 12 hours.
2. For compliance with UL standards the battery
backup period must be at least 24 hours.
Note: Only the LTT-AA2200LSDX8B battery
pack is approved for use by UL.
Time to Charge
80 % ( 13 Hrs)
80 % ( 30 Hrs) for all battery types
Optional Backup
Battery Pack
See "Backup Battery Options" above
See "Backup Battery Options" table above
Time to Charge
(optional backup
battery pack)
80 % ( 24 Hrs)
NA
Wired Detectors
Total (Sum)
Current
NA
36* mA max.
Site External Siren
Current (EXT)
NA
450* mA max @ 12.5 VDC when powered by
AC/DC (10.5 VDC when in standby mode)
Site Internal Siren
Current (INT)
NA
450* mA max @ 12.5 VDC when powered by
AC/DC (10.5 VDC when in standby mode)
* Total PowerMaster-30 G2 output current
(of INT & EXT sirens, PGM output and
detectors) cannot exceed 550 mA.
PGM
Current sink to control panel GND 100 mA
max.
Max. external DC voltage +30 VDC
Current sink to control panel GND 100 mA
max.
Max. external DC voltage +15 VDC
High Current /
Short Circuit
Protection
NA
All outputs are protected (automatic reset fuse)